Electronics Information flashcards

ASVAB Wiring & Safety Flashcards

16 flashcards on Wiring & Safety for the ASVAB Electronics Information subtest. Flip each card, check yourself with the matching game, or print the whole deck as a PDF.

About this deck

About the Wiring & Safety flashcards

Here you’ll work through how real wiring is sized, colored and protected. Cards include American Wire Gauge (AWG), the hot, neutral and equipment ground wires, the polarized plug, GFCI and AFCI devices, and the Class C fire. On the Electronics Information subtest, this helps with questions about which wire is thicker, which color carries voltage and how to respond safely to an electrical hazard.

Wire gauge runs backward from what you’d guess: a smaller AWG number means a thicker wire, so 12 AWG carries more current than 14 AWG. Also keep GFCI and AFCI apart, since a GFCI mainly prevents shocks and an AFCI mainly prevents fires. Go through Study mode first, test yourself with Matching, then try the matching practice test.

Want the full topic? Read our Electronics Information study guide.

Flip through 16 cards. Mark each one "Got it" or "Missed it"; missed cards come back until you know them all.

0 of 16 mastered

All 16 cards in this deck

Conductor
A material with loosely held electrons that lets current flow easily. Silver conducts best, but copper is used for most wiring because it is cheaper.
Insulator
A material that strongly resists current, such as rubber, glass, plastic, porcelain, or dry wood. Used to cover wires and prevent shocks.
American Wire Gauge (AWG)
The US system for wire size. A smaller gauge number means a thicker wire that can carry more current, so 12 AWG is thicker than 14 AWG.
Common household wire sizes
For copper house wiring, 14 AWG is used on 15-amp circuits, 12 AWG on 20-amp circuits, and 10 AWG on 30-amp circuits.
What affects a wire's resistance
A longer wire has more resistance; a thicker wire has less. Material matters too, and most metals' resistance rises as they get hotter.
US household voltages
Standard outlets supply 120 V AC. Large appliances like electric dryers, ranges, and central air use 240 V from two hot wires.
Hot wire colors
The hot (ungrounded) conductor carries voltage from the panel and is usually black or red. It is the wire most likely to shock you.
Neutral wire
The grounded conductor that carries current back to the panel to complete the circuit. Its insulation is white or gray.
Equipment ground wire
A safety wire that is green, green with a yellow stripe, or bare copper. It normally carries no current, only fault current.
Grounding
Connecting metal parts to earth through a low-resistance path. If a hot wire touches a metal case, current flows to ground and trips the breaker instead of shocking you.
Polarized plug
A plug with one blade wider than the other so it fits only one way. The wider blade is neutral, keeping switches on the hot side.
GFCI (ground-fault circuit interrupter)
Cuts power in a fraction of a second when hot and neutral currents differ by about 5 milliamps. Required near water: bathrooms, kitchens, garages, outdoors.
AFCI (arc-fault circuit interrupter)
A breaker or outlet that detects dangerous arcing from damaged or loose wiring and cuts power. It mainly prevents fires, while a GFCI mainly prevents shocks.
Class C fire
A fire involving energized electrical equipment. Never use water; use a CO₂ or dry-chemical extinguisher, and cut the power if you safely can.
Lockout/tagout (LOTO)
A safety procedure that shuts off an energy source, locks it, and tags it so no one can turn it back on while equipment is serviced.
Danger of electric shock
Current through the body, not voltage alone, causes injury. As little as about 50–100 milliamps across the chest can stop the heart.
Flashcard questions

Questions about this deck

What's in the Wiring & Safety flashcards?

This deck has 16 cards. The first set covers materials and wire size: conductors, insulators, American Wire Gauge, common household wire sizes and what changes a wire's resistance. The next set covers house wiring: 120 V and 240 V circuits, hot, neutral and ground wires, grounding and polarized plugs. The last set is safety: GFCI, AFCI, Class C fires, lockout/tagout and the danger of electric shock.

In US house wiring, the hot wire is usually black or red and carries voltage from the panel, so it's the one most likely to shock you. The neutral wire is white or gray and carries current back to the panel to complete the circuit. The equipment ground is green, green with a yellow stripe, or bare copper, and it normally carries current only during a fault.

A GFCI (ground-fault circuit interrupter) compares the current in the hot and neutral wires and cuts power if they differ by about 5 milliamps, which protects people from shock. That's why it's required near water, like bathrooms, kitchens, garages and outdoors. An AFCI (arc-fault circuit interrupter) watches for dangerous arcing from damaged or loose wiring and mainly prevents fires.

Test yourself

Ready for a Electronics Information practice test?